Interactive Intelligence

Use the following procedure to create an Interactive Intelligence adapter.

Procedure 

  1. Choose General Setup > Integration Adapters > Settings.

  2. Click Create, then select I3 Adapter.

  3. Enter the following settings:

    Field

    Description

    Adapter Name

    Enter a name for the adapter.

    Description

    Optional: Type a description that will help you distinguish this adapter from others.

    Startup Type

    Select one of the following startup types from the dropdown list:

    • Automatic—The adapter will start automatically with the Integration Service.

    • Manual—Will require manual startup.

    • Disabled—Prevents the adapter from running.

    DataSource

    Select a data source Third-party systems that provide data to the system, including employee and device states, and data change events. Typical data sources are phone switches, PBXs, or LANs. from the dropdown list. You can create data sources in Enterprise Manager (see the Recorder Configuration and Administration Guide).

    CIC Hostname

    The host name of the Interactive Intelligence switch (CIC server). In the presence of a switchover pair, the server name should be the primary CIC server name as configured during the switchover configuration of CIC server.

    Logon Id

    The CIC User Name for the user created for the Verint Recorder.

    Password

    The password of the Verint user created on the CIC server. Click the button beside the password field to enter and confirm the password, then click Set.

    The maximum password length is 1024 characters.

    Workstation

    The CIC workstation name created for the Recorder.

    ApplicationName

    A unique name used to identify the connection between the Interactive Intelligence Adapter and the Interactive Intelligence switch.

    Tag All Call Attributes

    Select this check box to obtain all call attributes from the switch.

    Note: It is recommended that you only use this setting to determine what call attribute information is required for tagging by the customer. All of the call attributes will appear in the section “customattributes” in the call events in the Integration Service Log file when DebugHigh mode is on.

    Once you have identified the call attributes that are required for tagging, disable Tag All Call Attributes and configure the call attributes required for tagging as described below.

  4. Under Advanced Settings, use the Add button to enter any Custom Attributes required for tagging (up to 255 characters).

    The available call attributes can be initially retrieved by enabling Tag All Call Attributes option described above.

  5. Click Save.

Supported Integration Service CTI adapters